1,937 research outputs found

    Thermoviscoplastic response of Ti-15-3 under various loading conditions

    Get PDF
    The long term objective is to develop a combined experimental analytic methodology for predicting the thermoviscoplastic behavior of the neat (i.e., unreinforced) titanium matrix. Once a constitutive model which adequately describes the behavior of titanium has been identified, the viscoplastic behavior of unidirectional composites will be predicted through the use of the rule-of-mixtures. A crucial aspect of the study is the selection of a constitutive model to describe the thermoviscoplastic behavior of titanium

    Resistance fail strain gage technology as applied to composite materials

    Get PDF
    Existing strain gage technologies as applied to orthotropic composite materials are reviewed. The bonding procedures, transverse sensitivity effects, errors due to gage misalignment, and temperature compensation methods are addressed. Numerical examples are included where appropriate. It is shown that the orthotropic behavior of composites can result in experimental error which would not be expected based on practical experience with isotropic materials. In certain cases, the transverse sensitivity of strain gages and/or slight gage misalignment can result in strain measurement errors

    Adaptive wall wind tunnels: A selected, annotated bibliography

    Get PDF
    This bibliography, with abstracts, consists of 257 citations arranged in chronological order. Selection of the citations was made for their value to researchers working to solve problems associated with reducing wall interference by the design, development, and operation of adaptive wall test sections. Author, source, and subject indexes are included

    Evaluating Consistency of Snow Water Equivalent Retrievals from Passive Microwave Sensors over the North Central U. S.: SSM/I vs. SSMIS and AMSR-E vs. AMSR2

    Get PDF
    For four decades, satellite-based passive microwave sensors have provided valuable snow water equivalent (SWE) monitoring at a global scale. Before continuous long-term SWE records can be used for scientific or applied purposes, consistency of SWE measurements among different sensors is required. SWE retrievals from two passive sensors currently operating, the Special Sensor Microwave Imager Sounder (SSMIS) and the Advanced Microwave Scanning Radiometer 2 (AMSR2), have not been fully evaluated in comparison to each other and previous instruments. Here, we evaluated consistency between the Special Sensor Microwave/Imager (SSM/I) onboard the F13 Defense Meteorological Satellite Program (DMSP) and SSMIS onboard the F17 DMSP, from November 2002 to April 2011 using the Advanced Microwave Scanning Radiometer for Earth Observing System (AMSR-E) for continuity. Likewise, we evaluated consistency between AMSR-E and AMSR2 SWE retrievals from November 2007 to April 2016, using SSMIS for continuity. The analysis is conducted for 1176 watersheds in the North Central U.S. with consideration of difference among three snow classifications (Warm forest, Prairie, and Maritime). There are notable SWE differences between the SSM/I and SSMIS sensors in the Warm forest class, likely due to the different interpolation methods for brightness temperature (Tb) between the F13 SSM/I and F17 SSMIS sensors. The SWE differences between AMSR2 and AMSR-E are generally smaller than the differences between SSM/I and SSMIS SWE, based on time series comparisons and yearly mean bias. Finally, the spatial bias patterns between AMSR-E and AMSR2 versus SSMIS indicate sufficient spatial consistency to treat the AMSR-E and AMSR2 datasets as one continuous record. Our results provide useful information on systematic differences between recent satellite-based SWE retrievals and suggest subsequent studies to ensure reconciliation between different sensors in long-term SWE records

    The yield and post-yield behavior of high-density polyethylene

    Get PDF
    An experimental and analytical evaluation was made of the yield and post-yield behavior of high-density polyethylene, a semi-crystalline thermoplastic. Polyethylene was selected for study because it is very inexpensive and readily available in the form of thin-walled tubes. Thin-walled tubular specimens were subjected to axial loads and internal pressures, such that the specimens were subjected to a known biaxial loading. A constant octahederal shear stress rate was imposed during all tests. The measured yield and post-yield behavior was compared with predictions based on both isotropic and anisotropic models. Of particular interest was whether inelastic behavior was sensitive to the hydrostatic stress level. The major achievements and conclusions reached are discussed

    Wind tunnel wall interference in V/STOL and high lift testing: A selected, annotated bibliography

    Get PDF
    This bibliography, with abstracts, consists of 260 citations of interest to persons involved in correcting aerodynamic data, from high lift or V/STOL type configurations, for the interference arising from the wind tunnel test section walls. It provides references which may be useful in correcting high lift data from wind tunnel to free air conditions. References are included which deal with the simulation of ground effect, since it could be viewed as having interference from three tunnel walls. The references could be used to design tests from the standpoint of model size and ground effect simulation, or to determine the available testing envelope with consideration of the problem of flow breakdown. The arrangement of the citations is chronological by date of publication in the case of reports or books, and by date of presentation in the case of papers. Included are some documents of historical interest in the development of high lift testing techniques and wall interference correction methods. Subject, corporate source, and author indices, by citation numbers, have been provided to assist the users. The appendix includes citations of some books and documents which may not deal directly with high lift or V/STOL wall interference, but include additional information which may be helpful

    Multiple Signaling Functions Of Song In A Polymorphic Species With Alternative Reproductive Strategies

    Get PDF
    Vocal traits can be sexually selected to reflect male quality, but may also evolve to serve additional signaling functions. We used a long-term dataset to examine the signaling potential of song in dimorphic white-throated sparrows (Zonotrichia albicollis). We investigated whether song conveys multifaceted information about the vocalizing individual, including fitness, species identity, individual identity, and morph. We also evaluated whether song traits correlate differently with fitness in the two morphs, as the more promiscuous strategy of white, relative to tan, morph males might impose stronger sexual selection. Males with high song rates achieved higher lifetime reproductive success, and this pattern was driven by white morph males. In addition, males that sang songs with many notes survived longer, but this pattern was less robust. Thus, song traits reflect differences in fitness and may more strongly affect fitness in the white morph. Song frequency was unrelated to fitness, body size, or morph, but was individual specific and could signal individual identity. Songs of the two morphs displayed similar frequency ratios and bandwidths. However, tan morph males sang songs with longer first notes, fewer notes, and higher variability. Thus, song could be used in morph discrimination. Variation in frequency ratios between notes was low and could function in conspecific recognition, but pitch change dynamics did differ between four different song types observed. Our results support a multiple messages model for white-throated sparrow song, in which different song traits communicate discrete information about the vocalizing individual

    Rapid method for determination of antimicrobial susceptibilities pattern of urinary bacteria

    Get PDF
    Method determines bacterial sensitivity to antimicrobial agents by measuring level of adenosine triphosphate remaining in the bacteria. Light emitted during reaction of sample with a mixture of luciferase and luciferin is measured

    Compression creep of filamentary composites

    Get PDF
    Axial and transverse strain fields induced in composite laminates subjected to compressive creep loading were compared for several types of laminate layups. Unidirectional graphite/epoxy as well as multi-directional graphite/epoxy and graphite/PEEK layups were studied. Specimens with and without holes were tested. The specimens were subjected to compressive creep loading for a 10-hour period. In-plane displacements were measured using moire interferometry. A computer based data reduction scheme was developed which reduces the whole-field displacement fields obtained using moire to whole-field strain contour maps. Only slight viscoelastic response was observed in matrix-dominated laminates, except for one test in which catastrophic specimen failure occurred after a 16-hour period. In this case the specimen response was a complex combination of both viscoelastic and fracture mechanisms. No viscoelastic effects were observed for fiber-dominated laminates over the 10-hour creep time used. The experimental results for specimens with holes were compared with results obtained using a finite-element analysis. The comparison between experiment and theory was generally good. Overall strain distributions were very well predicted. The finite element analysis typically predicted slightly higher strain values at the edge of the hole, and slightly lower strain values at positions removed from the hole, than were observed experimentally. It is hypothesized that these discrepancies are due to nonlinear material behavior at the hole edge, which were not accounted for during the finite-element analysis

    Application of luciferase assay for ATP to antimicrobial drug susceptibility

    Get PDF
    The susceptibility of bacteria, particularly those derived from body fluids, to antimicrobial agents is determined in terms of an ATP index measured by culturing a bacterium in a growth medium. The amount of ATP is assayed in a sample of the cultured bacterium by measuring the amount of luminescent light emitted when the bacterial ATP is reacted with a luciferase-luciferin mixture. The sample of the cultured bacterium is subjected to an antibiotic agent. The amount of bacterial adenosine triphosphate is assayed after treatment with the antibiotic by measuring the luminescent light resulting from the reaction. The ATP index is determined from the values obtained from the assay procedures
    • …
    corecore